Home Categories Send inquiry

2P 4Pole 40A 63A 500mA RCD Type B 10KA Type B RCCB for 11KW 22KW EV Wallbox

2P 4Pole 40A 63A 500mA RCD Type B 10KA Type B RCCB for 11KW 22KW EV Wallbox

Type B for all types of residual current, i.e. alternating, pulsating direct and smooth direct residual currents (IEC/ EN 62423). Direct residual currents may occur in industrial and commercial installations (and/or even in residential installations), where frequency inverters, photovoltaic power plants and other equipment with power semiconductor elements are applied.

When talking only about protective function, then the general term RCD – Residual Current Device is used. Only when specific properties or method of installation need to be characterized, a more precise term is used.


Electrical Features

ModelMIDA-100B
Type(wave form of the earth leakage sensed)B Type RCCB
Rated current In25A ,32A ,40A,63A, 80A,100A
Poles2Pole and 4Pole
Rated voltage Ue2Pole: 230V / 240V , 4Pole: 400V / 415V
Insulation voltage Ui500V
Rated frequency50/60Hz
Rated residual operation current(I n)30mA,100mA,300mA
Rated residual making and breaking capacity (I m)500(In=2540A) 630(In=63A)
Short-circuit current Inc= I c10000A
SCPD fuse10000
Break time under I n≤0.1s
Rated impulse withstand voltage(1.5/50) Uimp4000V
Dielectric test voltage at ind.Freq. for 1min2.5kV
Electrical life2,000 Cycles
Mechanical life4,000 Cycles

Installation 

Contact position indicatorYes
Protection degreeIP20
Ambient temperature(with daily average≤35°C)-5°C~+40°C
Storage temperature-25°C~+70°C
Terminal connection typeCable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable25mm2  18-3AWG
Terminal size top/bottom for busbar25mm2  18-3AWG
Tightening torque2.5Nm  22In-lbs
MountingOn DIN rail EN60715(35mm) by means of fast clip device
ConnectionFrom top and bottom

 Tripping Current Range

Lagging AngleI n>0.01AI n≤0.01A
0.35I n≤I≤1.4I n0.35I n≤I ≤2I n
90°0.25I n≤I≤1.4I n0.25I n≤I ≤2I n
135°0.11I n≤I≤1.4I n0.11I n≤I ≤2In
Detectable wave formPulsating direct current sensitiveSurge current proof
B class
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents,alternating residual sinusoidal currents up to 1000Hz,pulsating direct residual currents and for smooth direct residual currents,whether applied suddenly or increasing slowly.

They react to AC and pulsating DC fault current which reach 0 or almost 0 within one time period of the mains frequency.

RCCB’s surge capacity.
Not tripping at standardized 8/20 υs surge-current waves acc.to VDE 0432 Part 2 with surge current values of up to 250A.

Circuit Diagram 


  • 2P 4Pole 40A 63A 500mA RCD Type B 10KA Type B RCCB for 11KW 22KW EV Wallbox Related Video: